What Is Schedule 60 Steel Pipe?
Schedule 60 steel pipe is a standardized pipe wall-thickness designation used to specify the wall thickness of steel pipes according to their Nominal Pipe Size (NPS). It is commonly associated with ASME B36.10M, which covers dimensions of welded and seamless wrought steel pipes.
Unlike the pipe’s outside diameter, which remains fixed for a given NPS, the wall thickness varies according to the schedule number. Schedule 60 generally has a thicker wall than Schedule 40 but a thinner wall than Schedule 80 for comparable pipe sizes.
The wall thickness directly affects the pipe’s inside diameter, weight, and material consumption. For this reason, buyers need to consider both NPS and Schedule 60 when specifying steel pipes for industrial piping systems.
An important distinction: Schedule 60 is not a material grade or pressure rating. The actual pressure capacity depends on factors such as steel grade, pipe dimensions, operating temperature, design conditions, and the applicable piping code.
Schedule 60 Pipe Dimensions and Weight Chart
Schedule 60 steel pipe dimensions and weight are determined by the Nominal Pipe Size (NPS) and corresponding wall thickness. According to ASME B36.10M, each pipe size has a specified outside diameter (OD), wall thickness (WT), and nominal weight per unit length.
The following chart provides commonly used Schedule 60 pipe dimensions, including outside diameter, inside diameter, wall thickness, and theoretical weight. These values help buyers compare pipe specifications, estimate material requirements, and calculate transportation costs.
Schedule 60 Steel Pipe Dimensions and Weight Chart
| NPS (in.) | DN | OD (mm) | WT (mm) | ID (mm) | Weight (kg/m) |
| 8 | 200 | 219.1 | 10.31 | 198.48 | 53.09 |
| 10 | 250 | 273.0 | 12.70 | 247.60 | 81.53 |
| 12 | 300 | 323.8 | 14.27 | 295.26 | 108.93 |
| 14 | 350 | 355.6 | 15.09 | 325.42 | 126.72 |
| 16 | 400 | 406.4 | 16.66 | 373.08 | 160.13 |
| 18 | 450 | 457.2 | 19.05 | 419.10 | 205.84 |
| 20 | 500 | 508.0 | 20.62 | 466.76 | 247.84 |
| 22 | 550 | 558.8 | 22.22 | 514.36 | 294.03 |
| 24 | 600 | 609.6 | 24.61 | 560.38 | 355.04 |
Reference: ASME B36.10M-2018. Values are nominal plain-end pipe dimensions and theoretical weights.
For additional information on Schedule 60 pipe dimensions under ASME B36.10M, see our guide to ASME B36.10M Schedule 60 pipe.
Actual pipe weight may vary depending on manufacturing tolerances, material density, and end preparation. For procurement, buyers should confirm the required dimensions and applicable tolerances against the project specification.
Schedule 60 Pipe Wall Thickness
Schedule 60 pipe wall thickness varies according to Nominal Pipe Size (NPS). A larger pipe diameter generally requires a different nominal wall thickness under the same schedule designation. Therefore, Schedule 60 does not represent one fixed wall thickness across all pipe sizes.
Under ASME B36.10M, the specified wall thickness determines the pipe’s inside diameter and contributes to its overall weight. Buyers should check the corresponding wall thickness for each NPS rather than estimate it based on the pipe diameter.
To compare Schedule 60 with other common wall thickness designations, see our steel pipe schedule dimensions chart.
Schedule 60 Pipe Wall Thickness by Size
| NPS (in.) | OD (mm) | Schedule 40 WT (mm) | Schedule 60 WT (mm) | Schedule 80 WT (mm) |
| 4 | 114.3 | 6.02 | 8.56 | 8.56 |
| 6 | 168.3 | 7.11 | 10.97 | 10.97 |
| 8 | 219.1 | 8.18 | 10.31 | 12.70 |
| 10 | 273.0 | 9.27 | 12.70 | 15.09 |
| 12 | 323.8 | 10.31 | 14.27 | 17.48 |
| 14 | 355.6 | 11.13 | 15.09 | 19.05 |
| 16 | 406.4 | 12.70 | 16.66 | 21.44 |
| 18 | 457.2 | 14.27 | 19.05 | 23.83 |
| 20 | 508.0 | 15.09 | 20.62 | 26.19 |
| 24 | 609.6 | 17.48 | 24.61 | 30.94 |
Reference: ASME B36.10M dimensional data. Values are nominal wall thicknesses in mm.
Schedule 60 Pipe Pressure Rating: Calculation Example
Schedule 60 steel pipe does not have a universal pressure rating. Its pressure capacity depends on pipe dimensions, material properties, design temperature, and applicable piping codes. A practical way to understand its pressure capacity is to examine a specific pipe size and material grade.
For example, consider an NPS 10 Schedule 60 seamless steel pipe manufactured to ASTM A106 Grade B, with an outside diameter of 273.0 mm and a nominal wall thickness of 12.70 mm.
Under the following assumptions:
- Design temperature: 100°F (37.8°C)
- Allowable stress: 20,000 psi
- Manufacturing wall thickness tolerance: −12.5%
- Corrosion allowance: 0 mm
- Weld quality factor (E): 1.0
- Weld strength reduction factor (W): 1.0
Minimum Wall Thickness After Tolerance
t = 12.70 × (1 – 0.125) = 11.1125 mm
ASME B31.3 Internal Pressure Formula
P = (2SEWt) / (D – 2Yt)
The calculated pressure is approximately 1,683 psi (11.60 MPa).
This example illustrates how pipe size, wall thickness, and material properties influence pressure capacity. The result is not a universal pressure rating for NPS 10 Schedule 60 pipe. Actual design approval must account for all applicable code requirements, service conditions, additional allowances, and project-specific loading conditions.
Schedule 60 vs. Schedule 40 vs. Schedule 80
For the same NPS, Schedule 40, Schedule 60, and Schedule 80 have the same outside diameter but different wall thicknesses. The differences become clearer when comparing their dimensional specifications and theoretical weights.
Key Differences Between Schedule 40, 60, and 80
Taking NPS 8 and NPS 10 as examples:
| Parameter | NPS 8 Sch 40 | NPS 8 Sch 60 | NPS 8 Sch 80 | NPS 10 Sch 40 | NPS 10 Sch 60 | NPS 10 Sch 80 |
| OD (mm) | 219.1 | 219.1 | 219.1 | 273.0 | 273.0 | 273.0 |
| WT (mm) | 8.18 | 10.31 | 12.70 | 9.27 | 12.70 | 15.09 |
| ID (mm) | 202.74 | 198.48 | 193.70 | 254.46 | 247.60 | 242.82 |
| Weight (kg/m) | 42.55 | 53.09 | 64.57 | 61.13 | 81.53 | 96.30 |
Theoretical dimensions and weights based on carbon steel density of approximately 7,850 kg/m³.
What Do These Differences Mean for Buyers?
- Internal flow capacity:For NPS 10, the inside diameter decreases from 254.46 mm in Schedule 40 to 247.60 mm in Schedule 60 and 242.82 mm in Schedule 80. This affects the available flow area and should be considered during hydraulic calculations.
- Material and transportation costs:The theoretical weight of NPS 10 pipe increases from 61.13 kg/m in Schedule 40 to 81.53 kg/m in Schedule 60 and 96.30 kg/m in Schedule 80. This influences steel consumption, shipping weight, and installation requirements.
- Dimensional compatibility:All three schedules retain the same 273.0 mm outside diameter for NPS 10. However, their different wall thicknesses result in different inside diameters, which may affect connections and internal components.
The choice between these schedules should be based on the required wall thickness, flow conditions, design pressure, operating temperature, and applicable piping code rather than schedule number alone.
Where Is Schedule 60 Steel Pipe Used?
Schedule 60 steel pipe is used in industrial piping systems where a specific combination of wall thickness, pipe diameter, and mechanical strength is required. Its relatively thick wall compared with Schedule 40 makes it an option for projects requiring additional material thickness without moving to heavier pipe schedules.
Common applications include:
Industrial Fluid Transportation
Schedule 60 steel pipes can be used in industrial systems transporting water, process fluids, and other compatible media. Their wall thickness and internal diameter make them suitable for piping configurations where both flow requirements and mechanical design conditions must be considered.
Oil and Gas Industry
In oil and gas facilities, Schedule 60 pipes may be specified for process piping, utility lines, and supporting pipeline systems. Material grade, corrosion resistance, operating pressure, and temperature must be evaluated according to the project requirements.
Power Generation and Industrial Facilities
Power plants and industrial facilities use steel pipes in water supply, auxiliary piping, and various process systems. Schedule 60 may be selected when its dimensional specifications meet the required design conditions.
Infrastructure and Water Systems
Certain water transmission, treatment, and industrial infrastructure projects may specify Schedule 60 steel pipes. Depending on the service environment, additional internal or external protection, such as FBE or 3PE coating, may be required.
FAQ
Is Schedule 60 thicker than Schedule 40?
Yes. Schedule 60 generally has a thicker wall than Schedule 40 for the same NPS. However, the actual difference depends on the pipe size. For example, an NPS 10 Schedule 60 pipe has a wall thickness of 12.70 mm, compared with 9.27 mm for Schedule 40.
How is Schedule 60 pipe weight calculated?
The theoretical weight per meter of Schedule 60 carbon steel pipe can be calculated using:
W=0.0246615 X (OD-WT) X WT
Where OD and WT are measured in millimeters and W is expressed in kg/m. The formula assumes a steel density of approximately 7,850 kg/m³.
What is the standard for Schedule 60 steel pipe?
ASME B36.10M specifies dimensions for welded and seamless wrought steel pipes, including applicable Schedule 60 dimensions. It defines the relationship between nominal pipe size, outside diameter, and wall thickness. Material requirements must be specified separately, such as ASTM A53, ASTM A106, or API 5L, depending on the application.