Welcome to ALLLAND Steel Pipe Manufacturing.ASTM A795 Grade A Steel Pipe is a carbon steel pipe specifically manufactured for fire protection and automatic sprinkler systems. It is produced according to ASTM A795/A795M Standard Specification for Black and Hot-Dipped Zinc-Coated Welded and Seamless Steel Pipe for Fire Protection Use.

As a professional ASTM A795 Grade A Steel Pipe Manufacturer, ALLLAND supplies ERW welded and galvanized steel pipes for commercial buildings, industrial facilities, warehouses, and fire protection projects worldwide.ASTM A795 Grade A pipe offers excellent weldability, dimensional accuracy, corrosion resistance options, and reliable pressure performance for fire sprinkler applications.

Alllandsteel is a steel pipe manufacturer based in China with 25 years of experience

The facility spans 22,000 square meters, represents a RMB 700 million investment, and operates four production lines (JCOE, ERW, SMLS, SSAW) alongside five coating lines. 

With an annual production capacity of 250,000 tons, the factory covers specifications ranging from Ø406 to Ø1524 and holds multiple international certifications (API/ASTM/EN/ISO/JIS). Focused on steel pipes, creating value for you!

ASTM A795 Grade A

ASTM A795 Grade A is a standard for carbon steel pipe specifically intended for fire sprinkler systems.

The full title of the standard is: ASTM A795/A795M – Standard Specification for Black and Hot-Dipped Zinc-Coated (Galvanized) Welded and Seamless Steel Pipe for Fire Protection Use
Grade A represents the standard-strength classification within ASTM A795 and is primarily used for fire protection piping systems in buildings.

ASTM A795 Grade A Steel Pipe Overview

O.D.:

1/2″ – 24″

DN15–DN600

21.3 mm – 610 mm

W.T.:

2.0 mm – 25.4 mm

SCH 10, SCH 40, SCH 80

Length:

5.8 m / 6 m / 11.8 m / Customized

Pipe Type:

ERW / Seamless Steel Pipe

Material:

Carbon Steel

Steel Grades:

Grade A

Tube Ends& Surface Treatment:

Square, Chamfered; Black Skin, Pickled, Painted/Oiled for Rust Prevention

Delivery Conditions:

Grade, Specification, Furnace Number, Standard       

Key Features of ASTM A795 Grade A Pipe

ASTM A795 Grade A steel pipe is designed for reliable fire protection systems with the following advantages:

Excellent Weldability

Low carbon content provides good weldability and allows easy fabrication, threading, and grooving.

Reliable Pressure Performance

The pipe meets ASTM A795 mechanical requirements for fire sprinkler and fire water distribution systems.

Multiple Surface Options

Available in:

  • Black steel finish
  • Hot-dip galvanized coating
  • Customized coating solutions

Flexible Installation

Compatible with:

  • Grooved coupling systems
  • Threaded connections
  • Welding connections

ASTM A795 Grade A Steel Pipe Dimensions Table

ASTM A795 fire protection steel pipe is typically supplied in accordance with the ASME B36.10M / ASTM A795 dimensional standards; common specifications include Schedules 10, 40, and 80, with end configurations including plain end, threaded end, and grooved end.

ASTM A795 Grade A Steel Pipe Dimensions (Schedule 10)

Nominal Pipe Size (NPS) DN Outside Diameter (OD) mm Wall Thickness (WT) mm Weight kg/m Working Pressure Reference
1/2″ DN15 21.3 2.11 1.00 Fire Sprinkler
3/4″ DN20 26.7 2.11 1.28 Fire Sprinkler
1″ DN25 33.4 2.77 2.09 Fire Sprinkler
1-1/4″ DN32 42.2 2.77 2.69 Fire Sprinkler
1-1/2″ DN40 48.3 2.77 3.11 Fire Sprinkler
2″ DN50 60.3 2.77 3.93 Fire Sprinkler
2-1/2″ DN65 73.0 3.05 5.40 Fire Sprinkler
3″ DN80 88.9 3.05 6.60 Fire Sprinkler
4″ DN100 114.3 3.05 8.56 Fire Sprinkler
5″ DN125 141.3 3.40 11.56 Fire Sprinkler
6″ DN150 168.3 3.40 13.85 Fire Sprinkler
8″ DN200 219.1 3.76 19.85 Fire Sprinkler
10″ DN250 273.1 4.19 27.80 Fire Sprinkler
12″ DN300 323.9 4.57 35.90 Fire Sprinkler

ASTM A795 Grade A Steel Pipe Dimensions (Schedule 40)

NPSDNOD (mm)WT (mm)Weight (kg/m)Typical Application
1/2″DN1521.32.771.27Small sprinkler branch
3/4″DN2026.72.871.69Sprinkler piping
1″DN2533.43.382.50Sprinkler branch
1-1/4″DN3242.23.563.39Fire distribution
1-1/2″DN4048.33.684.05Fire distribution
2″DN5060.33.915.44Main sprinkler line
2-1/2″DN6573.05.168.63Main pipe
3″DN8088.95.4911.29Main pipe
4″DN100114.36.0216.07Fire water line
5″DN125141.36.5521.77Fire water line
6″DN150168.37.1128.26Fire riser
8″DN200219.18.1842.55Main fire pipeline
10″DN250273.19.2760.31Large fire system
12″DN300323.910.3181.47Fire water main

ASTM A795 Grade A Large Diameter Dimensions

NPSDNOD (mm)WT (mm)Weight (kg/m)
14″DN350355.611.1395.30
16″DN400406.412.70124.50
18″DN450457.014.27158.00
20″DN500508.015.09185.90
24″DN600610.017.48259.00

ASTM A795 Grade A Pipe End Types

End TypeDescriptionTypical Application
Plain End (PE)Pipe ends are supplied without threading or bevelingWelding, mechanical coupling, and general piping connections
Threaded End (TE)Pipe ends are threaded for direct connection with fittingsSmall-diameter fire sprinkler systems
Grooved End (GE)Pipe ends are roll-grooved or cut-grooved for coupling installationFire sprinkler systems using grooved couplings
Beveled End (BE)Pipe ends are beveled to facilitate weldingButt welding and field fabrication

ASTM A795 Grade A Chemical Composition

ASTM A795 Grade A carbon steel has controlled chemical limits to ensure weldability and mechanical performance.

ElementMaximum (%)
Carbon (C)0.25
Manganese (Mn)0.95
Phosphorus (P)0.035
Sulfur (S)0.035

ASTM A795 Grade A Mechanical Properties

PropertyASTM A795 Grade A Requirement
Yield Strength≥ 30,000 psi (205 MPa)
Tensile Strength≥ 48,000 psi (330 MPa)
Elongation≥ 25%

ASTM A795 Grade A vs Grade B Mechanical Properties

GradeYield StrengthTensile Strength
ASTM A795 Grade A205 MPa330 MPa
ASTM A795 Grade B240 MPa415 MPa

Grade B provides higher strength, while Grade A is widely used for normal fire sprinkler piping.

ASTM A795 Grade A Pipe Types

1) Black Steel Pipe

Used in:

  • Indoor fire sprinkler systems
  • Dry pipe systems
  • Wet pipe systems

2) Galvanized Steel Pipe

Hot-dip galvanized ASTM A795 Grade A pipe is used where corrosion resistance is required.

Applications:

  • Wet sprinkler systems
  • Humid environments
  • Underground fire protection piping (with proper protection)

Typical zinc coating:

Coating TypeZinc Thickness
Hot-dip galvanized≥ 1.8 oz/ft² (≈275 g/m²)

ASTM A795 Grade A Pipe Applications

ASTM A795 Grade A steel pipe is designed for reliable fire sprinkler systems, which are automatic fire protection systems used in commercial and industrial buildings.

Fire Protection Sector (Core Applications)
① Automatic sprinkler systems
② Fire water piping systems
③ Industrial fire protection

ASTM A795 Grade A vs ASTM A53 Grade B

FeatureASTM A795 Grade AASTM A53 Grade B
Main ApplicationFire sprinklerGeneral pressure piping
Yield Strength205 MPa240 MPa
Tensile Strength330 MPa415 MPa
Fire Protection ApprovalSpecifically designedGeneral purpose
CoatingBlack / GalvanizedBlack / Galvanized
Common UseSprinkler pipingWater, gas, structural

ASTM A795 Grade A Pipe with UL/FM Approval

Please note:
ASTM A795 ≠ UL/FM certification
ASTM A795 is a material and manufacturing standard, whereas:

  • UL (Underwriters Laboratories)
  • FM Global

belong to fire protection product certification systems.

In actual fire protection projects, the following is often required:
ASTM A795 Grade A + UL Listed / FM Approved

Specifically:

  • The steel pipe complies with the ASTM A795 standard.
  • It also meets fire protection certification requirements.

ALLLAND ASTM A795 Grade A Steel Pipe can be supplied as ERW welded pipe with black coating or hot-dip galvanized finish, manufactured according to ASTM A795 requirements, with options for UL/FM approved fire sprinkler projects, grooved ends, threaded ends, and third-party inspection (SGS/BV/TUV).

FAQ

What is ASTM A795 Grade A pipe used for?

ASTM A795 Grade A pipe is mainly used for automatic fire sprinkler systems, fire water pipelines, and industrial fire protection systems.

Yes. ASTM A795 Grade A pipes are available in both black steel and hot-dip galvanized finishes.

Grade B has higher mechanical strength, while Grade A is commonly used for standard fire sprinkler applications.